Boost Cooling System Efficiency and Reduce Energy use With ECONOWATT Ozone Water Treatment
Hidden Problems in Building and Factory Cooling Systems
Central air-conditioning (Chiller Systems) require condenser cooling water to reject heat. Over time, scale, algae, and microorganisms accumulate, reducing heat-transfer efficiency and wasting energy without you realizing it. Common issues include:
- Scale and rust buildup in condenser tubes
- Growth of algae and biofilm
- Declining water quality, resulting in a low COC (Cycles of Concentration)
- Higher electricity costs due to inefficient heat exchange
- Shorter equipment lifespan
- Risk of Legionella contamination
Ozone Solution: Eliminates Pathogens, Scale, and Biofilm in Cooling Systems
ECONOWATT developed an Ozone Generator for Condenser Water systems to improve water quality keeping it clean and disinfected while maintaining cooling performance. By using ozone instead of chemicals, the system reduces costs and extends equipment life.
Improves heat exchange efficiency. Reduces chiller energy use by 20–25%
Eliminates Legionella. Prevents biofilm and reduces scale
Raises conductivity cycles. Up to 10 cycles without chemicals
100% chemical-free. No chemicals required in the system
4G Monitoring System Real-time performance tracking
80% ozone injection efficiency. Delivers effective water disinfection
How ECONOWATT
Condenser Water System Works
Measure hardness, sediment, and microbial levels to design a system suited to actual water conditions.
Remove sediment and metal particles before the system to prevent condenser clogging.
Inject ozone into the cooling system to eliminate algae, biofilm, and Legionella without chemicals.
Use electrical attraction to capture calcium and magnesium ions, reduce scale formation, and improve heat-transfer efficiency.
Monitor water quality and operating status in real time with automatic alerts.
EHR (Electro Hardness Removal): ECONOWATT Innovation
Removes Ca²⁺ and Mg²⁺ minerals from the water before it enters the system.
Prevent new scale formation in the condenser.
Easy to clean — no chemicals required.
Increase COC up to 10 cycles and reduce blowdown water.
Save more than 10–20% of energy in chiller systems.
Heat-transfer efficiency increased by more than
30%
Scale and biofilm reduced by more than
90%
reduced by
COC increased up to
10 cycles
reducing blowdown water
Real Results from ECONOWATT Installations
Condenser Cooling Water Projects Trusted by Customers








Let ECONOWATT’s experts design the right water treatment and energy conservation solution for your industry, backed by guaranteed quality, standards, and measurable results.