Boost Cooling System Efficiency and Reduce Energy use With ECONOWATT Ozone Water Treatment

A condenser cooling-water treatment system powered by clean ozone energy 
 removing scale, biofilm, and pathogens while lowering energy costs in air-conditioning systems.

Hidden Problems in Building and Factory Cooling Systems

Central air-conditioning (Chiller Systems) require condenser cooling water to reject heat. Over time, scale, algae, and microorganisms accumulate, reducing heat-transfer efficiency and wasting energy without you realizing it. Common issues include:


  • Scale and rust buildup in condenser tubes
  • Growth of algae and biofilm
  • Declining water quality, resulting in a low COC (Cycles of Concentration)
  • Higher electricity costs due to inefficient heat exchange
  • Shorter equipment lifespan
  • Risk of Legionella contamination

Ozone Solution: Eliminates Pathogens, Scale, and Biofilm in Cooling Systems

ECONOWATT developed an Ozone Generator for Condenser Water systems to improve water quality keeping it clean and disinfected while maintaining cooling performance. By using ozone instead of chemicals, the system reduces costs and extends equipment life.

Improves heat exchange efficiency. Reduces chiller energy use by 20–25%

Eliminates Legionella. Prevents biofilm and reduces scale

Raises conductivity cycles. Up to 10 cycles without chemicals

100% chemical-free. No chemicals required in the system

4G Monitoring System Real-time performance tracking

80% ozone injection efficiency. Delivers effective water disinfection

How ECONOWATT
Condenser Water System Works

Condenser Water
Water Analysis

Measure hardness, sediment, and microbial levels to design a system suited to actual water conditions.

Pre-Treatment Filtration

Remove sediment and metal particles before the system to prevent condenser clogging.

Ozone Injection (Disinfection)

Inject ozone into the cooling system to eliminate algae, biofilm, and Legionella without chemicals.

Scale Removal by Electricity (EHR System)

Use electrical attraction to capture calcium and magnesium ions, reduce scale formation, and improve heat-transfer efficiency.

Smart Monitoring

Monitor water quality and operating status in real time with automatic alerts.

โซลูชันที่มากกว่าประสิทธิภาพ คือความยั่งยืน

EHR (Electro Hardness Removal): ECONOWATT Innovation

EHR (Electro Hardness Removal) is an electrolysis-based scale-control system designed by ECONOWATT in collaboration with MTEC. It reduces water hardness without chemicals helping reduce scale inside condenser tubes, increase COC, and lower energy costs.

Removes Ca²⁺ and Mg²⁺ minerals from the water before it enters the system.

Prevent new scale formation in the condenser.

Easy to clean — no chemicals required.

Increase COC up to 10 cycles and reduce blowdown water.

Save more than 10–20% of energy in chiller systems.

Heat-transfer efficiency increased by more than

30%
Scale and biofilm reduced by more than
90%
Chemical use
reduced by
100%
COC increased up to
10 cycles
reducing blowdown water

Real Results from ECONOWATT Installations

Condenser Cooling Water Projects Trusted by Customers

Let ECONOWATT’s experts design the right 
water treatment and energy conservation solution for your industry, backed by guaranteed quality, standards, and measurable results.